|本期目录/Table of Contents|

[1]江书庆,薄惠,刘宽浩,等.同型半胱氨酸电极的研制及其测定性能研究[J].生物医学工程研究,2016,03:205-208.
 JIANG Shuqing,BO Hui,LIU Kuanhao,et al.Preparation of Homocysteine Electrode and the Study of Determined Performance[J].Journal of Biomedical Engineering Research,2016,03:205-208.
点击复制

同型半胱氨酸电极的研制及其测定性能研究(PDF)

《生物医学工程研究》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2016年03期
页码:
205-208
栏目:
出版日期:
2016-09-25

文章信息/Info

Title:
Preparation of Homocysteine Electrode and the Study of Determined Performance
文章编号:
1672-6278 (2016)03-0205-04
作者:
江书庆薄惠刘宽浩李锟
黄河科技学院医学院,河南 郑州 450063
Author(s):
JIANG Shuqing BO Hui LIU Kuanhao LI Kun
School of Medicine, Huanghe Science and Technology College, Zhengzhou 450063,China
关键词:
同型半胱氨酸电极直接电位法同型半胱氨酸Nernst
Keywords:
Homocysteine Electrode Direct potential methodHomocysteineNernst
分类号:
R318
DOI:
-
文献标识码:
A
摘要:
建立一种血浆中同型半胱氨酸(HCY)的含量测定方法。以HCY为目标分子,α-甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯作交联剂,偶氮二异丁腈(AIBN)作为引发剂,制备了HCY分子印迹模板,并以此为电活性物质研制了HCY电极,用以建立血液中HCY的测定方法。HCY在5×10-3 mol/L~5×10-5 mol/L范围内与电池电动势呈现良好的Nernst响应,r为0.9992,并用大鼠血浆进行了加样回收,平均回收率为101.3%,RSD为2.71%。HCY电极响应性能良好,可用于真实样品的测定。
Abstract:
To develop a new method for determination of homocysteine in plasma. A homocysteine(HCY) ion selective electrode was fabricated with a molecularly imprinted polymer (MIP). The process was based on the synthesis of polymers with HCY as template, α-methacrylic acid (MAA) as functional monomer, and ethylene glycol dimethacrylate (EGDMA) as a crosslinker,2,2′-Azobis(2-methylpropionitrile)(AIBN) as initiator. The ion selective electrode was prepared with this HCY MIP as electric active substance, and was used to assay the HCY in plasma. The electromotive force 〖WTBX〗(E)〖WTBZ〗 exhibited a excellent Nernst response to HCY concentration over a range of 5×10-3 mol/L~5×10-5 mol/L, and average recovery rate was 101.3%. RSD was 2.71% . The HCY electrode can be used for determintion of real sample.