|本期目录/Table of Contents|

[1]刘盛锋,卓柳,倪东.胎儿颜面部三维超声基准标准切面自动校对系统的研究[J].生物医学工程研究,2016,04:229-233.
 LIU Shengfeng,ZHUO Liu,NI Dong.Automatic Alignment of the Reference Standard Planes of Fetal Face from Three dimensional Ultrasound Image[J].Journal of Biomedical Engineering Research,2016,04:229-233.
点击复制

胎儿颜面部三维超声基准标准切面自动校对系统的研究(PDF)

《生物医学工程研究》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2016年04期
页码:
229-233
栏目:
出版日期:
2016-12-25

文章信息/Info

Title:
Automatic Alignment of the Reference Standard Planes of Fetal Face from Three dimensional Ultrasound Image
文章编号:
1672-6278 (2016)04-0229-05
作者:
刘盛锋卓柳倪东
1.哈尔滨理工大学自动化学院,哈尔滨 150080; 2. 医学超声关键技术国家地方联合工程实验室, 广东省生物医学信息检测与超声成像重点实验室,深圳大学生物医学工程系,深圳 518060
Author(s):
LIU ShengfengZHUO LiuNI Dong
1. School of Automation, Harbin University of Science and Technology, Harbin 150080,China;2. National-Regional Key Technology Engineering Laboratory for Medical Ultrasound,Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging,Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
关键词:
胎儿颜面部三维超声基准标准切面目标检测特征提取
Keywords:
Fetal face Three-dimensional ultrasound Reference standard plane Object detection Feature extraction
分类号:
R318
DOI:
-
文献标识码:
A
摘要:
提出三维超声胎儿颜面部三正交基准标准切面自动校对系统。首先,通过自动检测胎儿双眼球定位正中矢状面;其次,通过自动检测正中矢状面上的面部轮廓线定位面额冠状切面;最后,以鼻骨、双眼球和面部轮廓线为参考校对水平横切面,从而自动定义胎儿颜面部三维基准向量。对80个三维超声体数据的实验结果表明,我们的自动校对系统与超声医生校对的正中矢状面、面额冠状切面和水平横切面三个基准标准切面的角度误差(degree)分别为:3.836±2.954、4.870±3.822、4.805±4.005,距离误差(毫米)分别为2.022±1.707、2.921±1.887、2.543±1.578。实验结果验证了本系统是可行的、可重复的和可靠的。
Abstract:
we proposed an automatic alignment system of the reference standard planes of fetal face from three-dimensional (3D) ultrasound image. First, the median sagittal plane (MSP) was localized based on the automatic detection of two eyeballs. Then, the facial coronary plane (FCP) was localized based on the automatic detection of facial profile line in the MSP. At last, the nasal bone, the eyeballs and the facial profile line were combined to localize the axial plane (AP) and define the fetal facial base vectors in 3D ultrasound. Experimental results on 80 3D ultrasound images showed that the degree errors of the MSP, FCP and AP planes by our automatic system were 3.836±2.954, 4.870±3.822 and 4.805±4.005, respectively. The distance errors (mm) of the MSP, FCP and AP planes by our automatic system were 2.022±1.707, 2.921±1.887 and 2.543±1.578, respectively. The results demonstrate the feasibility, repeatability and reliability of the developed system.

参考文献/References

备注/Memo

备注/Memo:
(收稿日期:2016-10-30)国家自然科学基金资助项目(61101026)。通信作者Email:nidong@szu.edu.cn。